{"status":"success","advisory":{"_id":"69a16ce12784d6e658dd9d4f","kb_acknowledgements":null,"kb_affected_list":["Astra Control Center","E-Series SANtricity OS Controller Software","FAS/AFF Baseboard Management Controller (BMC) - A250/500f/C250","NetApp Manageability SDK","NetApp Shift Toolkit","ONTAP Select Deploy administration utility","ONTAP tools for VMware vSphere 10"],"kb_bad_data":false,"kb_cve":["CVE-2002-20001"],"kb_exploitation":"Public","kb_fixes":[{"product":"Astra Control Center","fixes":[],"instructions":null,"wontfix":true,"eos_link":"https://mysupport.netapp.com/info/communications/CPC-00622.html"},{"product":"NetApp Manageability SDK","fixes":[{"link":"https://mysupport.netapp.com/site/products/all/details/netapp-manageability-sdk/downloads-tab/download/60427/9.8P12","cves":[]}],"instructions":"","wontfix":false,"eos_link":null}],"kb_impact":"Successful exploitation of this vulnerability could lead to Denial of Service (DoS).\r\n<br><br>\r\nE-Series SANtricity OS Controller Software:<br>\r\nAffected only when SSH is enabled - it is disabled by default. ","kb_internal_notes":[{"burt":"","jira":"PSIRT-26641","product":"AFF Baseboard Management Controller (BMC) - A700s"},{"burt":"","jira":"PSIRT-26642","product":"AFF/ASA/FAS Baseboard Management Controller (BMC) - A1K/A90/A70/C80/FAS90/FAS70"},{"burt":"","jira":"PSIRT-26643","product":"AFF/ASA/FAS Baseboard Management Controller (BMC) - A50/A30/A20/C60/C30/FAS50"},{"burt":"","jira":"CAIQUM-8355","product":"Active IQ Unified Manager for Linux"},{"burt":"","jira":"CAIQUM-8356","product":"Active IQ Unified Manager for Microsoft Windows"},{"burt":"","jira":"CAIQUM-8357","product":"Active IQ Unified Manager for VMware vSphere"},{"burt":"","jira":"PSIRT-26645","product":"Astra Control Center"},{"burt":"","jira":"PSIRT-26646","product":"Astra Control Provisioner"},{"burt":"","jira":"CONTAPEXT-3526","product":"Brocade Fabric Operating System Firmware"},{"burt":"","jira":"CONTAPEXT-3527","product":"Brocade SAN Navigator (SANnav)"},{"burt":"","jira":"CONTAP-647050","product":"Cloud Volumes ONTAP Mediator"},{"burt":"","jira":"PSIRT-26649","product":"E-Series SANtricity OS Controller Software"},{"burt":"","jira":"PSIRT-26650","product":"Element .NET SDK"},{"burt":"","jira":"PSIRT-26651","product":"Element JAVA SDK"},{"burt":"","jira":"PSIRT-26652","product":"Element Plug-in for vCenter Server"},{"burt":"","jira":"PSIRT-26653","product":"Element Powershell Tools"},{"burt":"","jira":"PSIRT-26654","product":"Element Python SDK"},{"burt":"","jira":"PSIRT-26655","product":"FAS/AFF Baseboard Management Controller (BMC) - 8300/8700/A400/C400"},{"burt":"","jira":"PSIRT-26656","product":"FAS/AFF Baseboard Management Controller (BMC) - A250/500f/C250"},{"burt":"","jira":"PSIRT-26657","product":"FAS/AFF Baseboard Management Controller (BMC) - A320"},{"burt":"","jira":"PSIRT-26658","product":"FAS/AFF Baseboard Management Controller (BMC) - A800/C800"},{"burt":"","jira":"PSIRT-26659","product":"FAS/AFF Baseboard Management Controller (BMC) - A900/9500"},{"burt":"","jira":"PSIRT-26660","product":"FAS/AFF Baseboard Management Controller (BMC) - C190/A150/A220/FAS2720/FAS2750"},{"burt":"","jira":"PSIRT-26661","product":"FAS/AFF Baseboard Management Controller (BMC) - FAS2820"},{"burt":"","jira":"PSIRT-26662","product":"FAS/AFF Service Processor - A300/8200"},{"burt":"","jira":"PSIRT-26663","product":"FAS/AFF Service Processor - A700/9000"},{"burt":"","jira":"PSIRT-26664","product":"Global File Cache"},{"burt":"","jira":"PSIRT-26665","product":"Management Services for Element Software and NetApp HCI"},{"burt":"","jira":"CMCCTB-150","product":"MetroCluster Tiebreaker"},{"burt":"","jira":"PSIRT-26667","product":"NetApp Console Agent"},{"burt":"","jira":"PSIRT-26668","product":"NetApp Console Agent OVA"},{"burt":"","jira":"PSIRT-26671","product":"NetApp HCI Baseboard Management Controller (BMC) - H610S"},{"burt":"","jira":"PSIRT-26672","product":"NetApp LOADER 8.x"},{"burt":"","jira":"CNMSDK-169","product":"NetApp Manageability SDK"},{"burt":"","jira":"PSIRT-26674","product":"NetApp SMI-S Provider"},{"burt":"","jira":"PSIRT-26673","product":"NetApp Shift Toolkit"},{"burt":"","jira":"PSIRT-26675","product":"NetApp SolidFire & HCI Management Node"},{"burt":"","jira":"PSIRT-26676","product":"NetApp SolidFire & HCI Storage Node (Element Software)"},{"burt":"","jira":"CXCP-1331","product":"NetApp XCP NFS"},{"burt":"","jira":"CXCP-1332","product":"NetApp XCP SMB"},{"burt":"","jira":"CONTAP-647079","product":"ONTAP 9"},{"burt":"","jira":"CAVSHIM-313","product":"ONTAP Antivirus Connector"},{"burt":"","jira":"CDEPLOY-4506","product":"ONTAP Select Deploy administration utility"},{"burt":"","jira":"PSIRT-26680","product":"ONTAP tools for VMware vSphere 10"},{"burt":"","jira":"ICI-18106","product":"OnCommand Insight"},{"burt":"","jira":"CXPLAT-1888","product":"SnapCenter Plug-in for VMware vSphere"},{"burt":"","jira":"PSIRT-26682","product":"SnapGathers"},{"burt":"","jira":"PSIRT-26683","product":"StorageGRID (formerly StorageGRID Webscale)"},{"burt":"","jira":"PSIRT-26684","product":"StorageGRID Baseboard Management Controller (BMC) - SG6060/SGF6024/SG100/SG1000"},{"burt":"","jira":"PSIRT-26685","product":"StorageGRID Baseboard Management Controller (BMC) - SG6160/SGF6112/SG110/SG1100"},{"burt":"","jira":"PSIRT-26686","product":"StorageGRID Baseboard Management Controller - (BMC) SG5812/SG5860"},{"burt":"","jira":"PSIRT-26687","product":"Terraform Provider for ONTAP"},{"burt":"","jira":"PSIRT-26688","product":"Trident"},{"burt":"","jira":"PSIRT-26689","product":"Trident Autosupport"}],"kb_investigating_list":["Global File Cache","Management Services for Element Software and NetApp HCI","MetroCluster Tiebreaker","NetApp Console Agent OVA","NetApp SMI-S Provider","NetApp SolidFire & HCI Management Node","NetApp SolidFire & HCI Storage Node (Element Software)","NetApp XCP NFS","NetApp XCP SMB","SnapCenter Plug-in for VMware vSphere","SnapGathers","Terraform Provider for ONTAP"],"kb_num":"9010000","kb_ref":["https://nvd.nist.gov/vuln/detail/CVE-2002-20001"],"kb_rev_history":[{"comment":"Initial Public Release","date":"20260227","version":"1.0"},{"comment":"Element Python SDK and Element Powershell Tools moved to Products Not Affected","date":"20260227","version":"2.0"},{"comment":"E-Series SANtricity OS Controller Software 11.x added to Impact, ONTAP tools for VMware vSphere 10 and E-Series SANtricity OS Controller Software 11.x moved to Affected Products, ONTAP Antivirus Connector and OnCommand Insight moved to Products Not Affected","date":"20260303","version":"3.0"},{"comment":"NetApp Manageability SDK moved to Affected Products","date":"20260305","version":"4.0"},{"comment":"NetApp Shift Toolkit moved to Affected Products","date":"20260310","version":"5.0"},{"comment":"Astra Control Provisioner, Trident and Trident Autosupport moved to Products Not Affected","date":"20260312","version":"6.0"},{"comment":"ONTAP Select Deploy administration utility moved to Affected Products","date":"20260313","version":"7.0"},{"comment":"FAS/AFF Baseboard Management Controller (BMC) - A250/500f/C250 moved to Affected Products, FAS/AFF Baseboard Management Controller (BMC) - A900/9500, AFF/ASA/FAS Baseboard Management Controller (BMC) - A50/A30/A20/C60/C30/FAS50, AFF/ASA/FAS Baseboard Management Controller (BMC) - A1K/A90/A70/C80/FAS90/FAS70, FAS/AFF Baseboard Management Controller (BMC) - A320, FAS/AFF Baseboard Management Controller (BMC) - C190/A150/A220/FAS2720/FAS2750, FAS/AFF Service Processor - A300/8200, FAS/AFF Baseboard Management Controller (BMC) - A800/C800, FAS/AFF Baseboard Management Controller (BMC) - FAS2820 and FAS/AFF Service Processor - A700/9000 moved to Products Not Affected","date":"20260316","version":"8.0"},{"comment":"NetApp Console Agent and Active IQ Unified Manager for VMware vSphere moved to Products Not Affected","date":"20260430","version":"9.0"},{"comment":"NetApp Manageability SDK added to Software Versions and Fixes","date":"20260513","version":"10.0"},{"comment":"E-Series SANtricity OS Controller Software added to Workarounds","date":"20260601","version":"11.0"},{"comment":"Brocade Fabric Operating System Firmware and Brocade SAN Navigator (SANnav) moved to Products Not Affected","date":"20260608","version":"12.0"},{"comment":"Astra Control Center moved to Won't Fix status","date":"20260609","version":"13.0"}],"kb_revised_list":[],"kb_scoring":{"CVE-2002-20001":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"},"kb_scoring_calc":[{"cve_id":"CVE-2002-20001","range":"HIGH","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"}],"kb_status":"Interim","kb_summary":"The Diffie-Hellman Key Exchange Protocol is susceptible to a vulnerability which when successfully exploited could lead to Denial of Service (DoS).","kb_title":"CVE-2002-20001 Diffie-Hellman Key Exchange Protocol Vulnerability in NetApp Products","kb_unaffected_list":["AFF BIOS - A700s","AFF Baseboard Management Controller (BMC) - A700s","AFF/ASA/FAS BIOS - A1K/A90/A70/C80/FAS90/FAS70","AFF/ASA/FAS BIOS - A50/A30/A20/C60/C30/FAS50","AFF/ASA/FAS Baseboard Management Controller (BMC) - A1K/A90/A70/C80/FAS90/FAS70","AFF/ASA/FAS Baseboard Management Controller (BMC) - A50/A30/A20/C60/C30/FAS50","ATTO FibreBridge - 7600N","Active IQ Config Advisor","Active IQ Unified Manager for Linux","Active IQ Unified Manager for Microsoft Windows","Active IQ Unified Manager for VMware vSphere","Active IQ mobile app","Astra Control Provisioner","Brocade Fabric Operating System Firmware","Brocade SAN Navigator (SANnav)","Cloud Volumes ONTAP Mediator","Data Infrastructure Insights Acquisition Unit","Data Infrastructure Insights Telegraf Agent","Data Infrastructure Insights and Data Secure Storage Workload Security Agent","E-Series BIOS","E-Series SANtricity Unified Manager and Web Services Proxy","Element .NET SDK","Element HealthTools","Element JAVA SDK","Element Plug-in for vCenter Server","Element Powershell Tools","Element Python SDK","FAS/AFF BIOS - 2820","FAS/AFF BIOS - 8300/8700/A400/C400","FAS/AFF BIOS - A250/500f/C250","FAS/AFF BIOS - A300/8200/C190/A220/2720/2750/A150","FAS/AFF BIOS - A320","FAS/AFF BIOS - A700/9000","FAS/AFF BIOS - A800/C800","FAS/AFF BIOS - A900/9500","FAS/AFF Baseboard Management Controller (BMC) - 8300/8700/A400/C400","FAS/AFF Baseboard Management Controller (BMC) - A320","FAS/AFF Baseboard Management Controller (BMC) - A800/C800","FAS/AFF Baseboard Management Controller (BMC) - A900/9500","FAS/AFF Baseboard Management Controller (BMC) - C190/A150/A220/FAS2720/FAS2750","FAS/AFF Baseboard Management Controller (BMC) - FAS2820","FAS/AFF Service Processor - A300/8200","FAS/AFF Service Processor - A700/9000","IOM12 SAS Disk Shelf Firmware","IOM12B SAS Disk Shelf Firmware","IOM12C SAS Disk Shelf Firmware","IOM12E SAS Disk Shelf Firmware","IOM12F SAS Disk Shelf Firmware","IOM12G SAS Disk Shelf Firmware","MetroCluster DataCollector","Multipath I/O (SANtricity DSM for Windows MPIO)","NetApp Console Agent","NetApp Data Classification","NetApp DataOps Toolkit","NetApp E-Series Host Collection","NetApp E-Series SANtricity Collection","NetApp HCI Baseboard Management Controller (BMC) - H610S","NetApp HCI Storage Node BIOS","NetApp Kubernetes Monitoring Operator","NetApp LOADER 8.x","NetApp NFS Plug-in for VMware VAAI","NetApp ONTAP PowerShell Toolkit (PSTK)","NetApp SolidFire Plug-in for vRealize Orchestrator (SolidFire vRO)","NetAppDocs","ONTAP 9","ONTAP Antivirus Connector","ONTAP Mediator","OnCommand Insight","RcfFileGenerator for MetroCluster IP","SAN Host Utilities for Linux","SAN Host Utilities for Windows","SANtricity Storage Plugin for vCenter","SRA Plugin for Linux","SRA Plugin for Windows","SnapCenter","SolidFire Storage Replication Adapter","Storage Manager for ProxMox","StorageGRID (formerly StorageGRID Webscale)","StorageGRID BIOS SG1000/SG100/SG1100/SG110","StorageGRID BIOS SG5660/SG5612/SG5760/SG5712","StorageGRID BIOS SG5812/SG5860","StorageGRID BIOS SG6060/SGF6024/SGF6112/SG6160","StorageGRID Baseboard Management Controller (BMC) - SG6060/SGF6024/SG100/SG1000","StorageGRID Baseboard Management Controller (BMC) - SG6160/SGF6112/SG110/SG1100","StorageGRID Baseboard Management Controller - (BMC) SG5812/SG5860","System Manager 9.x","Trident","Trident Autosupport","Trident Protect"],"kb_workarounds":"E-Series SANtricity OS Controller Software:<br>\r\nEnsure that SSH remains disabled (the default). ","ntap_advisory_id":"NTAP-20260227-0010","adv_id":"ntap-20260227-0010","published_date":"2026-02-27T00:00:00","updated_date":"2026-06-09T00:00:00","inserted_date":"2026-06-09T16:25:12.752000","modified_date":null}}