{"status":"success","advisory":{"_id":"683547225b16347a91c39cda","kb_acknowledgements":null,"kb_affected_list":[],"kb_bad_data":false,"kb_cve":["CVE-2017-5705","CVE-2017-5708","CVE-2017-5711","CVE-2017-5712","CVE-2017-5706","CVE-2017-5709","CVE-2017-5707","CVE-2017-5710"],"kb_exploitation":"Not public","kb_fixes":[],"kb_impact":"Successful exploitation of these vulnerabilities could allow an attacker to impersonate the ME/SPS/TXE, thereby impacting local security feature attestation validity, load and execute arbitrary code outside the visibility of the user and operating system, or cause a system crash or system instability.","kb_internal_notes":[{"burt":"","jira":"","product":"E-Series SANtricity OS Controller Software 8.x"},{"burt":"","jira":"","product":"FAS/AFF BIOS"},{"burt":"","jira":"","product":"NetApp Cloud Backup (formerly AltaVault)"},{"burt":"","jira":"","product":"NetApp SolidFire & HCI Storage Node (Element Software)"},{"burt":"","jira":"","product":"Service Processor"}],"kb_investigating_list":[],"kb_num":"9010000","kb_ref":["https://security-center.intel.com/advisory.aspx?intelid=INTEL-SA-00086&languageid=en-fr","https://www.intel.com/content/www/us/en/support/articles/000025619/software.html"],"kb_rev_history":[{"comment":"Initial Public Release, Final status","date":"20171120","version":"1.0"}],"kb_revised_list":[],"kb_scoring":{"CVE-2017-5705":"CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H","CVE-2017-5706":"CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H","CVE-2017-5707":"CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H","CVE-2017-5708":"CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:N","CVE-2017-5709":"CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:N","CVE-2017-5710":"CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:N","CVE-2017-5711":"CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","CVE-2017-5712":"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H"},"kb_scoring_calc":[{"cve_id":"CVE-2017-5705","range":"HIGH","score":8.2,"vector":"CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H"},{"cve_id":"CVE-2017-5706","range":"HIGH","score":8.2,"vector":"CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H"},{"cve_id":"CVE-2017-5707","range":"HIGH","score":8.2,"vector":"CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H"},{"cve_id":"CVE-2017-5708","range":"HIGH","score":7.5,"vector":"CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:N"},{"cve_id":"CVE-2017-5709","range":"HIGH","score":7.5,"vector":"CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:N"},{"cve_id":"CVE-2017-5710","range":"HIGH","score":7.5,"vector":"CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:N"},{"cve_id":"CVE-2017-5711","range":"MEDIUM","score":6.7,"vector":"CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H"},{"cve_id":"CVE-2017-5712","range":"HIGH","score":7.2,"vector":"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H"}],"kb_status":"Final","kb_summary":"Multiple NetApp products incorporate Intel chipsets. Intel® Management Engine (ME) firmware versions 11.0/11.5/11.6/11.7/11.10/11.20, Intel® Server Platform Services (SPS) firmware version 4.0, and Intel® Trusted Execution Engine (TXE) firmware version 3.0 are susceptible to vulnerabilities that could allow an attacker to gain unauthorized access to a platform, Intel® ME features, and 3rd party secrets protected by the ME, SPS, or TXE. No NetApp products ship affected versions of the firmware.","kb_title":"Intel SA-00086 Management Engine Vulnerabilities in NetApp Products","kb_unaffected_list":["7-Mode Transition Tool","ATTO FibreBridge","Active IQ Unified Manager (formerly OnCommand Unified Manager) for Linux 7.3 and above","Active IQ Unified Manager (formerly OnCommand Unified Manager) for VMware vSphere 9.5 and above","Active IQ Unified Manager (formerly OnCommand Unified Manager) for Windows 7.3 and above","Brocade Fabric Operating System Firmware","Brocade Network Advisor Software","Clustered Data ONTAP","Clustered Data ONTAP Antivirus Connector","Data ONTAP operating in 7-Mode","E-Series SANtricity Management Plug-ins (VMware vCenter)","E-Series SANtricity OS Controller Software 11.x","E-Series SANtricity OS Controller Software 8.x","E-Series SANtricity Storage Manager","E-Series SANtricity Web Services (REST API) for Web Services Proxy","Element Plug-in for vCenter Server","FAS/AFF BIOS","Host Utilities - SAN for Linux","Host Utilities - SAN for Windows","MetroCluster Tiebreaker for clustered Data ONTAP","NetApp Cloud Backup (formerly AltaVault)","NetApp Cloud Backup OST Plug-in (formerly AltaVault OST Plug-in)","NetApp Converged Systems Advisor Agent","NetApp HCI Compute Node (Bootstrap OS)","NetApp Manageability SDK","NetApp NFS Plug-in for VMware VAAI","NetApp Plug-in for Symantec NetBackup","NetApp SANtricity SMI-S Provider","NetApp SMI-S Provider","NetApp Service Level Manager","NetApp SolidFire & HCI Storage Node (Element Software)","NetApp Storage Encryption","NetApp VASA Provider for Clustered Data ONTAP 7.2 and above","ONTAP Select Deploy administration utility","OnCommand API Services","OnCommand Cloud Manager","OnCommand Insight","OnCommand System Manager 9.x","OnCommand Unified Manager for 7-Mode (core package) ","OnCommand Workflow Automation","Open Systems SnapVault Agent","RAID Controller CTS2600 Legacy Engenio","Service Processor","Single Mailbox Recovery","Snap Creator Framework","SnapCenter","SnapDrive for Unix","SnapDrive for Windows","SnapManager for Exchange","SnapManager for Hyper-V","SnapManager for MS SQL","SnapManager for Oracle","SnapManager for SAP","SnapManager for Sharepoint","Storage Replication Adapter for Clustered Data ONTAP for VMware vSphere 7.2 and above","Storage Services Connector","StorageGRID (formerly StorageGRID Webscale)","StorageGRID Webscale NAS Bridge","StorageGRID9 (9.x and prior)","System Setup","Virtual Storage Console for VMware vSphere 7.2 and above"],"kb_workarounds":"None.","ntap_advisory_id":"NTAP-20171120-0001","adv_id":"ntap-20171120-0001","published_date":"2017-11-20T00:00:00","updated_date":"2017-11-20T00:00:00","inserted_date":"2025-05-27T05:01:22.032000","modified_date":null}}