{"status":"success","advisory":{"_id":"683547215b16347a91c39c9d","kb_acknowledgements":null,"kb_affected_list":["Clustered Data ONTAP","NetApp SolidFire & HCI Storage Node (Element Software)","NetApp VASA Provider for Clustered Data ONTAP 7.2 and above"],"kb_bad_data":false,"kb_cve":["CVE-2016-2776"],"kb_exploitation":"Public","kb_fixes":[{"product":"NetApp SolidFire & HCI Storage Node (Element Software)","fixes":[{"link":"https://mysupport.netapp.com/products/solidfire/11.0/","cves":[]}],"instructions":"","wontfix":false,"eos_link":null},{"product":"NetApp VASA Provider for Clustered Data ONTAP 7.2 and above","fixes":[{"link":"https://mysupport.netapp.com/NOW/download/software/vasa_cdot/7.0/","cves":[]}],"instructions":"","wontfix":false,"eos_link":null},{"product":"Clustered Data ONTAP","fixes":[{"link":"https://mysupport.netapp.com/NOW/download/software/ontap/8.3.2P8/","cves":[]},{"link":"https://mysupport.netapp.com/NOW/download/software/ontap/9.0P2","cves":[]}],"instructions":"","wontfix":false,"eos_link":null}],"kb_impact":"Successful exploitation of this vulnerability by remote attackers could result in a denial-of-service (DoS).","kb_internal_notes":[{"burt":"1039917","jira":"","product":"Clustered Data ONTAP"},{"burt":"","jira":"SECURITY-284","product":"NetApp SolidFire & HCI Storage Node (Element Software)"},{"burt":"1039919","jira":"","product":"NetApp VASA Provider for Clustered Data ONTAP 7.2 and above"},{"burt":"1039918","jira":"","product":"ONTAP Select Deploy administration utility"},{"burt":"1039920","jira":"","product":"OnCommand Balance"},{"burt":"1039921","jira":"","product":"OnCommand Performance Manager (Unified Manager Performance Pkg)"},{"burt":"1039922","jira":"","product":"OnCommand Unified Manager for Clustered Data ONTAP"}],"kb_investigating_list":[],"kb_num":"9010000","kb_ref":["https://www.us-cert.gov/ncas/current-activity/2016/09/27/ISC-Releases-Security-Updates-BIND","https://kb.isc.org/article/AA-01419/0","https://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-2776"],"kb_rev_history":[{"comment":"Initial Public Release","date":"20160930","version":"1.0"},{"comment":"OnCommand Performance Manager (Unified Manager Performance Pkg) & OnCommand Unified Manager for Clustered Data ONTAP (6.x) moved to Products Not Affected","date":"20161014","version":"2.0"},{"comment":"Clustered Data ONTAP moved to Affected Products, OnCommand Balance moved to Products Not Affected","date":"20161025","version":"3.0"},{"comment":"Corrected the numeric CVSS score","date":"20161031","version":"4.0"},{"comment":"Clustered Data ONTAP added to Software Versions and Fixes","date":"20161130","version":"5.0"},{"comment":"NetApp VASA Provider for Clustered Data ONTAP moved to Affected Products and added to Software Versions and Fixes","date":"20170920","version":"6.0"},{"comment":"Element Software (formerly SolidFire Element OS) added to Software Versions and Fixes, Final status","date":"20181211","version":"7.0"}],"kb_revised_list":[],"kb_scoring":{"CVE-2016-2776":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"},"kb_scoring_calc":[{"cve_id":"CVE-2016-2776","range":"HIGH","score":7.5,"vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"}],"kb_status":"Final","kb_summary":"<span style=\"font-size: 12px;\">Multiple NetApp products incorporate the ISC BIND libraries. ISC BIND versions 9.0.0 through 9.9.9-P2, 9.9.3-S1 through 9.9.9-S3, 9.10.x through 9.10.4-P2, and 9.11.0a1 through 9.11.0rc1 are susceptible to a vulnerability which when successfully exploited could result in a denial-of-service (DoS) attack. This advisory will be updated as additional information becomes available.</span>","kb_title":"CVE-2016-2776 ISC BIND Vulnerability in Multiple NetApp Products","kb_unaffected_list":["7-Mode Transition Tool","ATTO FibreBridge","Brocade Fabric Operating System Firmware","Brocade Network Advisor Software","Clustered Data ONTAP Antivirus Connector","Data ONTAP operating in 7-Mode","E-Series SANtricity Management Plug-ins (VMware vCenter)","E-Series SANtricity Storage Manager","E-Series SANtricity Web Services (REST API) for Web Services Proxy","FAS/AFF BIOS","Host Utilities - SAN for Linux","Host Utilities - SAN for Windows","MetroCluster Tiebreaker for clustered Data ONTAP","NetApp Cloud Backup (formerly AltaVault)","NetApp Cloud Backup OST Plug-in (formerly AltaVault OST Plug-in)","NetApp Manageability SDK","NetApp NFS Plug-in for VMware VAAI","NetApp Plug-in for Symantec NetBackup","NetApp SANtricity SMI-S Provider","NetApp SMI-S Provider","NetApp Storage Encryption","ONTAP Select Deploy administration utility","OnCommand API Services","OnCommand Balance","OnCommand Cloud Manager","OnCommand Insight","OnCommand Performance Manager (Unified Manager Performance Pkg)","OnCommand System Manager 9.x","OnCommand Unified Manager for 7-Mode (core package) ","OnCommand Unified Manager for Clustered Data ONTAP","OnCommand Workflow Automation","Open Systems SnapVault Agent","RAID Controller CTS2600 Legacy Engenio","Service Processor","Single Mailbox Recovery","Snap Creator Framework","SnapCenter","SnapDrive for Unix","SnapDrive for Windows","SnapManager for Exchange","SnapManager for Hyper-V","SnapManager for MS SQL","SnapManager for Oracle","SnapManager for SAP","SnapManager for Sharepoint","Storage Replication Adapter for Clustered Data ONTAP for VMware vSphere 7.2 and above","Storage Services Connector","StorageGRID (formerly StorageGRID Webscale)","StorageGRID Webscale NAS Bridge","StorageGRID9 (9.x and prior)","System Setup","Virtual Storage Console for VMware vSphere 7.2 and above"],"kb_workarounds":"<span style=\"font-size: 12px;\">None.</span>","ntap_advisory_id":"NTAP-20160930-0001","adv_id":"ntap-20160930-0001","published_date":"2016-09-30T00:00:00","updated_date":"2018-12-11T00:00:00","inserted_date":"2025-05-27T05:01:21.091000","modified_date":null}}